| Areva T&D | ||
The Transformer Services Department of Areva T&D's service business can provide specialist technical services associated with the provision of spares, inspection, maintenance, movement, installation, disposal, repair and up rating of transformers and tapchangers |
The Company’s Service Engineers have working experience on tapchangers of all manufacturers and are qualified to carry out major maintenance on all types, at site or at the Stafford Transformer works on a single or term contract basis. |
We have extensive experience in the movement and relocation and uprating of all sizes of transformers up to the largest Generator and Transmission units, in countries all over the world. |
The Drycol Refrigerated Breather System. Transformers operating at high voltages must have their insulating oil and paper insulation as dry as possible in order to prevent failure due to the accelerated ageing effects. |
The Drycol Breather (A) operates by drawing moist, warm air (B) from an air space or from outside via the air inlet tube (C), and returning it to the conservator (D) as cold dry air. A series of thermoelectric modules are used to alternately cool and heat the units vertical central duct (E) in an automatic continuously repeated cycle, extracting moisture as frost and ice, and melting it to escape via a drain tube (F). |
|
| CEM | ||
CEM offers a complete range of LV terminal bushings. |
We provide a two-component polyurethane casting system designed for the manufacture of power distribution equipment. |
We have the tooling required to offer a comprehensive range of cast-resin monoblocks used in transformers. |
Our monoblock bushing conductors are available in 1,700A, 2,500A, 3,150A, and 4,000A versions. |
The four-way CT block is manufactured from epoxy resin with four brass inserts with M6 thread on each end. |
|
| CG Power Systems | ||
Installation of compact SLIM® transformer in wind turbine with NOMEX insulation and silicone liquid; product range up to 5,5MVA/36kV. |
Liquid-filled distribution transformers 100kVA to 10MVA/36kV; special distribution transformers such as Big DT concept with a product range up to 15MVA/36kV. |
Power transformers 5MVA to 575MVA/525kV, auto-transformers up to 700MVA/525kV and HVDC station transformers up to 315MVA/500kVDC. |
Compact substation designs such as transformer switch units (TSU), WindSubs or modular substations; AIS and GIS substations up to 500kV. |
Mobile (hybrid) substations and mobile transformers up to 245kV. |
|
| ESI Group | ||
With ESI on-line vacuum dry-out units, drying of transformer windings can take place while the transformer remains in normal service. |
ESI tap-changer filter units remove moisture and particulates in insulating oil, which helps maintain electrical properties. |
Vacuum dryer / degasser units for field or factory use and versatile transformer oil filter units. |
ESI portable filter units are simple to use and plug into a standard domestic power supply. |
On-line transformer oil regeneration restores the oil to new oil condition and removes sludge and other contaminants. |
|
| GarrettCom | ||
GarrettCom manufactures a wide range of product categories, including managed switches, unmanaged switches and hubs and serial communications. |
A comparison of three grades of hardened products. |
A typical substation's network infrastructure. |
Garrett offers DX’s range of industrial routers, including the DX1000-IFR model. |
Garrett provides the 6KQ managed field switch. |
|
| Lucy Switchgear | ||
Our ground mounted secondary switchgear range covers Sabre, Trident and Scimitar as well as HV metering units. |
Switchgear automation. |
We provide rural and substation disconnectors and switchgear. |
Power connectors - we have in-depth knowledge in providing substation connectors up to 145kV and accessories. |
Lucy Switchgear LV distribution products feature Trifca, fuse distribution, indoor LV and mini pillars. |
|
| Ormazabal | ||
Ormazabal provides protection, automation and remote control solutions for renewable energy applications. |
Ormazabal offers a wide range of transformer substations for medium voltage secondary distribution applications. |
Ormazabal provides electrical switchgear and automation devices for secondary distribution networks. |
Ormazabal provides air and gas insulated switchgear for primary distribution networks. |
Ormazabal manufactures distribution transformers immersed in dielectric liquid in accordance with current international standards. |
|
| Permali Wallace | ||
Transformers, switchgears, generators, motors and control panels for electrical industries. |
Tension plates, lifting bar, fishplates stud nuts that are applicable for generators and transformers. |
A wide range of moulding compounds and components of Permaglass and Permaglass tubes. |
Permacast, Permawood and Permali products that are used in transformers and generators. |
||
| RITZ Instrument Transformers | ||
Cast resin power transformers. |
Medium-voltage instrument transformers. |
Low-voltage instrument transformers. |
| Tecsystem | ||
Temperature monitoring unit, for 8 RTD input channels with separate A/D measuring signal converter. |
Combined unit for temperature monitoring and cooling control system for casted resin MV transformers. |
Cross flow fan for cooling of casted resin MV transformers. |
Tecsystem offices and factory in Corsico. |
||
| TP Power Services | ||
TP Power Services has dedicated itself to constantly developing its quality management system and now meets the new 2008 standards. |
Design and manufacture of core, windings and on-load tap-changer for a 60MVA, 66/11.8kV, OFAF, 50Hz three-phase power transformer for a heavy-industry steel manufacturer in the north of the UK. |
Erection, installation, and pre-commissioning tests on 500MVA generator step-up transformers for the transmission of electrical power directly to the National Grid substation situated nearby. |
A set of 40MVA core and windings being lifted into position for re-tanking at our inspection and testing facility in Rugby on a five-week premium repair and refurbishment package. |
The positioning of a 10MVA three-phase liquid-filled distribution transformer within an industrial substation following removal from another of the client's sites. |
|