Home > Industry Projects > Combined-Cycle Gas Turbine (CCGT) > San Isidro II 400MW GTCC
Specifications - San Isidro II 400MW GTCC , Chile
| Key Data |
| Start of operation | Initial stage (gas turbine only operation) from March 2007, full power generation February 2008. |
| Output | 400MW |
| Plant type | Gas turbine combined-cycle (GTCC) |
| Location | Near Quillota city, about 130km northwest of the capital Santiago |
| Estimated investment | Around $190m |
| Key Players |
| Plant owner | Endesa (Empresa Nacional De Electricidad S.A. Chile |
| Main contractors | Mitsubishi Heavy Industries, Ltd. (MHI) and Mitsubishi Electric Corporation. |
| Maintenance | Mitsubishi has signed a 12-year maintenance contract. |
| Plant Details |
| Gas Turbines | M701F gas turbine with two-bearing single-shaft construction, cold-end power drive and axial exhaust. |
| Steam units | Steam turbine, heat recovery steam generator (HRSG) and two generators. |
| Fuel | Dual natural gas and oil fired |